FRIENDS.

terça-feira, 31 de dezembro de 2024

Feliz Ano Novo


 O ano novo é a oportunidade perfeita para renovar nossa fé e esperança. Que cada dia seja um convite à gratidão e à perseverança, mesmo nos desafios. Que Deus nos guie em cada decisão, trazendo paz ao coração e luz aos caminhos. 

domingo, 10 de novembro de 2024

MOTHER

 Mother combines with flower, with love

It is with everything that transcends.
It just doesn't match the longing that remains, and that doesn't go away.

segunda-feira, 7 de outubro de 2024

Varig


 

quarta-feira, 20 de março de 2024

FIRE PROTECTION - APU FIRE EXTINGUISHING


When there is a fire condition, the APU fire handle switch on the engine and APU fire control panel unlocks. When you pull the APU fire warning handle switch up, a signal goes to these components:   

   APU generator control unit - opens the APU generator breaker    

   APU control unit - shuts down the APU.    

   When you turn the fire warning handle switch right or left, 28v dc goes to the APU extinguisher bottle. This causes the APU fire extinguisher bottle squib to release the extinguishing agent.   

   You get the same results when you use the APU remote control panel P28. When you pull the fire handle switch on the P28 panel, a signal goes to these components:   

   APU generator control unit - opens the APU generator breaker    

   APU electronic control unit - shuts down the APU.    

   The bottle discharge switch also arms.   

   The bottle discharge switch sends 28v dc to the APU extinguisher bottle. This causes the APU extinguisher bottle squib to release the extinguishing agent.   

   When the APU fire extinguisher bottle pressure is less than 250 psi, the pressure switch makes the amber APU BOTTLE DISCHARGED light on the engine and APU fire control panel come on.

EQUIPMENT COOLING SMOKE DETECTION


 EQUIPMENT COOLING SMOKE DETECTION


The supply system and the exhaust system have a smoke detector. The detectors monitor for smoke. Relays give the logic that controls the operation of the smoke detection system.   

   If smoke is detected, the detector sends an alarm signal for these:   

   Indication in the flight compartment    

   Operation of the automatic reconfiguration for the smoke clearance mode    

   Configuration of the purge mode for the supply system.    

   Smoke clearance mode operation has an interface with these operations in the air conditioning system:   

   Flow control and shutoff valve    

   Recirculation fans    

   Equipment cooling fans    

   Overboard exhaust valve.    

   See the air conditioning chapter for more information about those operations (CHAPTER 21).   

   A test panel on the J23 junction box in the EE compartment lets you do a test of the smoke detectors and system operation.